AnalytikJena UK > Sum Parameters > Automation | Accessories

Accessories

The user-friendly plug & play concept ensures a maximum in variability allowing you to optionally combine the modules to set up a system meeting your specific needs. Thus, the multi N/C®-Series analyzers are suitable for most diverse analytical requirements. Moreover, the modular design enables later individual extension and modification. The systems are available with both direct injection and flow injection with injection volumes of up to 3 ml.

TOC analysis on liquids
 
AOX/EOX Analysis
TOC analysis on solids
  


TOC analysis on liquids


direct injection technology  

APG 60 Autosampler  

  


Sampler

  • APG 64 xyz autosampler for multi N/C® 3100
    Automatic xyz-sampler for up to 64 vials á 30 ml. Each sample can individually be stirred which is very important for the analysis of samples containing particles. The stirring speed is adjustable to 10 levels selected by the software. Including: sample tray, 64 sample vials, rinsing vessel, stirring bars, manual
  • APG 60 xyz autosampler for multi N/C® 2100, 2100 S
    xyz autosampler for up to 60 vials á 10 ml . Each sample can be individually stirred which is especially important for the analysis of samples containing particles.
  • APG 49 xyz autosampler for multi N/C® UV HS, multi N/C® pharma HS
    Automatic xyz-sampler for up to 49 vials á 50 ml.
  • EPA sampler with piercing function
    Automatic xyz sampler with 64 positions for EPA sample vessels (septum-sealed with screw-top) á 40 ml. Each sample is individually stirred and homogenized with a contamination-free magnetic stirrer prior to sampling. Special piercing canulas are used to take the samples from the sealed vessels. They also allow the samples to be blown out inside the sealed vessel.


Extra

  • swab-test module
    The Swab-Test for the TOC analyzer multi N/C® pharma HS is a module for the direct determination of carbon for cleaning validation by "swab-procedure".

 

top


TOC analysis on solids


Sample introduction for  
TOC analysis on solids  

  


Solid Modules

  • HT 1300
    High-Temperature Solids Combustion System for multi N/C® 2100, 2100 S, 3100 and multi N/C® UV HS (carbon analysis) - Solids module with combustion furnace for the analysis of carbon in solids with sample gas supply system and basic device connection kit. The furnace temperature is adjustable up to 1,300° C. Weighed portions of up to 3 g.
  • HT 1500
    High-Temperature Solids Combustion System for multi N/C® 2100 S, 3100 only (carbon analysis) - Solids module with combustion furnace for the analysis of carbon in solids with sample gas supply system and basic device connection kit. The furnace temperature is adjustable up to 1,500° C. Weighed portions of up to 3 g.
  • Double Furnace
    Liquids and solids can be analyzed without the need for an additional solids module, simple operation and quick changeover from liquid to solid analysis and vice versa.


Sample Dispensers

  • Solid autosampler FPG 21
    Sampler for solid, semi-solids and liquid materials for the TOC and TC determination with the high temperature modules HT 1500 in combination with the TOC analyzers multi N/C® 2100 and multi N/C® 3100.
    The samples were weighed in ceramic or quartz boats and automatically introduced into the combustion system. The speed of the sample introduction can be selected by the software which allows the analysis of very reactive samples.

 

top


AOX/EOX Analysis

  


Systems for sample preparations

  • AP 2P Column Method Option
    The AP 2P Adsorption Pump is an automatic adsorption system for sample preparation for AOX analysis acc. to the column method in compliance with DIN EN 1485 and ISO 9562. The system allows simultaneous processing of two samples of a volume of 10...225ml with the washing volume also being selectable between 10 and 225 ml. Sample volumes, washing volume and flow rate are electronically controlled. The program run includes aspiration of sample and nitrate wash solution and an automatic multiple washing step that prevents carry over especially in the enrichment of samples of high salt contents. The LCD screen for clear display of nominal values of sample and washing volumes as well as of the actual sample and washing volumes ensures easy operation of the adsorption module.
    The rugged mechanical pressure system allows a high pressure to be applied and features a high particle-handling capability.
    The use of sterile syringes that may be replaced when necessary efficiently prevents carry over and cross contamination.
    The system is compatible with adsorption columns of other make thus allowing universal use.
  • APV 26 Adsorption System
    Fully automatic sample preparation system for AOX analysis according to the column method as per DIN EN 1485 and ISO 9562 incl. control computer and initial kit.
    The APV 26 Adsorption System allows easy and convenient preparation of up to 26 samples, for instance for overnight runs, for AOX analysis acc. to the column method as per DIN EN 1485.
    Unlike conventional systems, the individual samples are processed strictly sequentially so that the first samples are available within a few minutes. The samples can be analyzed on every AOX analyzer.

  • DF 3U Pressure Filtration Unit
    The DF 3U Pressure Filtration Unit is suitable both for processing AOX samples by the batch method and the column method. It can simultaneously process up to 3 samples of up to 180 ml volume.
    The water/activated-carbon or water/activated-carbon/slurry mixtures produced in shaking are pressed into quartz containers by the overpressure of up to 2 bar produced by a pump. The quartz containers are accommodated in a fixture that is directly screwed to the sample vessel. The transfer of the activated carbon or the activated carbon/slurry mixture into the quartz container is performed quantitatively. As filters are not being used, a filter blank need not be taken into account.
    When the filtration unit is used for sample preparation acc. to the column method, duplex or triplex columns are screwed to the sample vessel. The flow rate is predefined by the integrated nozzles.
    When requested, the pressure pump may also be pressurized with an inert auxiliary gas.
    All components are chemically resistant and can be easily cleaned.
    Pressure-tested sample vessels as well as a front door made of acrylic glass ensure the necessary operational safety.


Autosampler

  • APG 36
    Autosampler for multi X® 2000 for max. 36 quartz containers (18 x 6) (column method). Autosampler for automatic feed of up to 36 quartz containers from sample preparation according to the column method. The electronic monitoring system ensures safe operation. Cross-contamination and ambient influences are excluded by the use of a cover.
    Conversion from column to batch method is by a simple change of the turntable.
  • APG 25
    Autosampler for multi X® 2000 for max. 25 quartz containers (20 x 10) (batch method). Autosampler for automatic feed of up to 25 Quartz containers from sample preparation according to the batch method. The electronic monitoring system ensures safe operation. Cross-contamination and ambient influences are excluded by the use of a cover. Conversion from batch to column method is by a simple change of the turntable.

Modules

  • EOX module for direct injection with autoinjector
    EOX module for the determination of EOX with the AOX/TOX analyzer multi X® 2000. The samples are directly injected the special reactor through a septa. The controlled injection is accomplished by an autoinjector.
  • EOX module for direct injection with autosampler
    EOX module for the determination of EOX with the AOX/TOX analyzer multi X® 2000. The samples are directly injected into the special reactor through a septa. The injection is accomplished by a programmable autosampler for up to 32 (optionally 105) samples.
  • POX module for AOX analyzer
    System for the analysis of volatile organic halogen compounds in water as well as in soil and slurry.

Extra

  • Automatic H2SO4 replacement unit for multi X® 2000
    The automatic sulfuric acid replacement unit allows problem-free unattended long-term operation of the multi X® 2000 even with those analytical methods usually involving the generation of larger quantities of water and thus a faster dilution of sulfuric acid in the drying vessel, such as the slurry method, EOX analysis. Moreover, it adds to the already existing high operating comfort in using the multi X® 2000. The software of the multi X® 2000 permits the regeneration cycles of the sulfuric acid in the drying vessel as well as the volume to be freely selected. An acid-resistant pump module evacuates the used up sulfuric acid from the drying vessel into a waste vessel and conveys new sulfuric acid from the dispensing vessel into the receiving flask.
  • Upgrade Kit multi X® 2000 for cooled coulometer cell
    A control system keeps the electrolyte temperature of the coulometer cell below room temperature thus avoiding premature vaporization of electrolyte and permitting large sample batches to be analyzed without the need for exchanging the electrolyte.
    Reliability and long-term stability are increased and the signal-to-noise ratio improved.
  • AQS software
    The multiAQS software was specially designed for the multiWin® software package. It provides data transfer from the multi X® 2000 AOX analyzer and from the multi N/C®. Besides, it allows manual entry of optional measurement results for control cards as per DIN standard.

 

top

 